2x Marstek Venus E 3.0 vs Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000
Short answer
We don't judge which of the 2x Marstek Venus E 3.0 and the Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 pays back sooner: the price of Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 is older than 90 days, but your own use and panels can change that. In the terraced house: 2x Marstek Venus E 3.0 25 years or more, Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 more than 30 years.
We compare only what we calculate, from our catalogue. No maker or shop pays for a place or an outcome. How we calculate · who pays us.
How they differ
Marks and payback for the terraced house.
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | 2x Marstek Venus E 3.0 | Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 |
|---|---|---|
| Usable capacity | 9.2 kWh | 9.1 kWh |
| Power | 5.0 kW, own group | 4.0 kW, installed |
| Price | €2,848 incl. installationprice of 1 October 2026, marstek.nl | €7,250 incl. installationprice of 8 April 2026, anteas.nl |
| Price per usable kWh | €310 | €795 |
| Warranty | 10 years or 6,000 cycles · at least 80% capacity remaining | 10 yearsinverter: 5 years |
| Backup power | emergency socket, 2 x 2,500 W | whole home, 4,000 W, with a transfer switch · solar charging during an outage |
| Home Assistant | community integration | official integration |
| Dynamic contract | yes, in its own app | yes, in its own app |
| Payback | 25 years or more | more than 30 years |
2x Marstek Venus E 3.0: Cash-flow scenario over 10 years
This repeats the reference-year saving. It is a scenario, not a forecast or a claim about how long the equipment will last.
10 years, 0.0% real discount rate. Prices and policy stay at the 2027 reference, including proposed tax rates where not final. Payments are counted at the end of each year after commissioning.
| Net present value after investment | −€1,778 |
|---|---|
| Cash balance after investment | −€1,778 |
| Discounted payback | Not within this scenario |
No equipment ageing, replacement, residual value or extra maintenance and supplier fees are assumed. Costs already included in the annual saving remain included. Imbalance-trading income is excluded.
| Year | Net cash flow | Balance after investment |
|---|---|---|
| 1 | €107 | −€2,741 |
| 2 | €107 | −€2,634 |
| 3 | €107 | −€2,527 |
| 4 | €107 | −€2,420 |
| 5 | €107 | −€2,313 |
| 6 | €107 | −€2,206 |
| 7 | €107 | −€2,099 |
| 8 | €107 | −€1,992 |
| 9 | €107 | −€1,885 |
| 10 | €107 | −€1,778 |
Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000: Cash-flow scenario over 10 years
This repeats the reference-year saving. It is a scenario, not a forecast or a claim about how long the equipment will last.
10 years, 0.0% real discount rate. Prices and policy stay at the 2027 reference, including proposed tax rates where not final. Payments are counted at the end of each year after commissioning.
| Net present value after investment | −€6,105 |
|---|---|
| Cash balance after investment | −€6,105 |
| Discounted payback | Not within this scenario |
No equipment ageing, replacement, residual value or extra maintenance and supplier fees are assumed. Costs already included in the annual saving remain included. Imbalance-trading income is excluded.
| Year | Net cash flow | Balance after investment |
|---|---|---|
| 1 | €114 | −€7,136 |
| 2 | €114 | −€7,021 |
| 3 | €114 | −€6,907 |
| 4 | €114 | −€6,792 |
| 5 | €114 | −€6,678 |
| 6 | €114 | −€6,563 |
| 7 | €114 | −€6,449 |
| 8 | €114 | −€6,334 |
| 9 | €114 | −€6,220 |
| 10 | €114 | −€6,105 |
All specifications
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | 2x Marstek Venus E 3.0 | Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 |
|---|---|---|
| Of 10 kWh in, you get back | 7.5–8.0 kWhone independent test | 8.3–8.9 kWhestimate from the datasheet |
| Reads your grid use via | P1 meter · clamp meter | clamp meter |
| Standby use | €23 a year | €31 a year |
| Feed-in left over | ≈ 840 kWh (without: 1,910) | ≈ 970 kWh (without: 1,910) |
| Savings from 2027 | €62–115 a year | €68–123 a year |
✓ Better for this home: only where the difference is larger than the uncertainty, with the reason under the row name. Unknown: not stated in the sources we use (datasheet, maker, shop).
Ordinary socket: 800 W at most. More power needs its own group.
Per example home
Show as table
| Home | Product | Payback |
|---|---|---|
| Terraced | 2x Marstek Venus E 3.0 | ≈ 29 years (25 years or more) |
| Terraced | Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 | > 30 years (more than 30 years) |
| Semi-detached | 2x Marstek Venus E 3.0 | ≈ 10 years (9–11 years) |
| Semi-detached | Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 | > 30 years (more than 30 years) |
| Heat pump | 2x Marstek Venus E 3.0 | ≈ 15 years (13–21 years) |
| Heat pump | Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 | > 30 years (more than 30 years) |
Terraced: the figures
2,900 kWh a year, 3 kWp of solar panels, fixed contract
No winner over the whole range for this home: the likely payback ranges overlap. Where one product is ahead in nearly every case we calculated, the row says so.
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | 2x Marstek Venus E 3.0 | Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 |
|---|---|---|
| Feed-in left over | ≈ 840 kWh (without: 1,910) | ≈ 970 kWh (without: 1,910) |
| Savings from 2027 | €62–115 a year | €68–123 a year |
| Payback | 25 years or more | more than 30 years |
Semi-detached: the figures
3,500 kWh a year, 5 kWp of solar panels, dynamic contract
No winner over the whole range for this home: the likely payback ranges overlap. Where one product is ahead in nearly every case we calculated, the row says so.
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | 2x Marstek Venus E 3.0 | Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 |
|---|---|---|
| Feed-in left over | ≈ 2,160 kWh (without: 3,580) | ≈ 2,450 kWh (without: 3,580) |
| Savings from 2027 | €259–308 a year | €192–242 a year |
| Payback | 9–11 years | more than 30 years |
Heat pump: the figures
3,000 kWh household use plus a heat pump that replaced 1,200 m³ of gas, 6 kWp of solar panels, fixed contract
No winner over the whole range for this home: the likely payback ranges overlap. Where one product is ahead in nearly every case we calculated, the row says so.
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | 2x Marstek Venus E 3.0 | Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 |
|---|---|---|
| Feed-in left over | ≈ 2,580 kWh (without: 4,240) | ≈ 2,740 kWh (without: 4,240) |
| Savings from 2027 | €139–226 a year | €141–230 a year |
| Payback | 13–21 years | more than 30 years |
Questions people ask
Which pays back sooner, the 2x Marstek Venus E 3.0 or the Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000?
We don't judge which of the 2x Marstek Venus E 3.0 and the Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 pays back sooner: the price of Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 is older than 90 days, but your own use and panels can change that. In the terraced house: 2x Marstek Venus E 3.0 25 years or more, Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 more than 30 years. In the terraced house: 2x Marstek Venus E 3.0 25 years or more, Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 more than 30 years. In the semi-detached house: 2x Marstek Venus E 3.0 9–11 years, Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 more than 30 years. In the home with a heat pump: 2x Marstek Venus E 3.0 13–21 years, Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 more than 30 years.
Which costs less per kWh of storage, the 2x Marstek Venus E 3.0 or the Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000?
The 2x Marstek Venus E 3.0 costs €310 per usable kWh (€2,848, price of 1 October 2026); the Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 costs €795 per usable kWh (€7,250, price of 8 April 2026).
Do the 2x Marstek Venus E 3.0 and the Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 have backup power?
2x Marstek Venus E 3.0: emergency socket, 2 x 2,500 W; Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000: whole home, 4,000 W, with a transfer switch · solar charging during an outage.
Do the 2x Marstek Venus E 3.0 and the Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000 work with a dynamic contract and Home Assistant?
Dynamic contract: 2x Marstek Venus E 3.0: yes, in its own app; Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000: yes, in its own app. Home Assistant: 2x Marstek Venus E 3.0: community integration; Victron + Pylontech MultiPlus-II 48/5000 + 2x US5000: official integration.
How did you calculate this?
With our own engine, for 3 invented example homes, hour by hour under the rules from 2027 (no net metering), with the prices in our catalogue. Each result is a range over 22 variants of the same home: how you use power, the direction of the panels, the weather and the energy price. We only mark a product better when it is ahead in at least 9 of 10 of those cases.