Growatt AURA 5000 vs Marstek Venus E 3.0
Short answer
For most homes, the Growatt AURA 5000 and the Marstek Venus E 3.0 pay back about equally fast, according to our calculation, but your own use and panels can change that. In the terraced house: Growatt AURA 5000 9–14 years, Marstek Venus E 3.0 10–15 years.
We compare only what we calculate, from our catalogue. No maker or shop pays for a place or an outcome. How we calculate · who pays us.
How they differ
Marks and payback for the terraced house.
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | Growatt AURA 5000 | Marstek Venus E 3.0 |
|---|---|---|
| Usable capacity | 4.5 kWh | 4.6 kWh |
| Power | 0.8 kW, socket | 0.8 kW, socket |
| Price | €1,208price of 1 October 2026, plugin-batterij.nl | €1,174price of 1 October 2026, marstek.nl |
| Price per usable kWh | €267 | €255 |
| Warranty | 10 years | 10 years or 6,000 cycles · at least 80% capacity remaining |
| Backup power | emergency socket, 2,500 W | emergency socket, 2,500 W |
| Home Assistant | none | community integration |
| Dynamic contract | yes, in its own app (uncertain) | yes, in its own app |
| Payback | 9–14 years | 10–15 years |
Growatt AURA 5000: Cash-flow scenario over 10 years
This repeats the reference-year saving. It is a scenario, not a forecast or a claim about how long the equipment will last.
10 years, 0.0% real discount rate. Prices and policy stay at the 2027 reference, including proposed tax rates where not final. Payments are counted at the end of each year after commissioning.
| Net present value after investment | €59 |
|---|---|
| Cash balance after investment | €59 |
| Discounted payback | End of year 10 |
No equipment ageing, replacement, residual value or extra maintenance and supplier fees are assumed. Costs already included in the annual saving remain included. Imbalance-trading income is excluded.
| Year | Net cash flow | Balance after investment |
|---|---|---|
| 1 | €127 | −€1,081 |
| 2 | €127 | −€955 |
| 3 | €127 | −€828 |
| 4 | €127 | −€701 |
| 5 | €127 | −€575 |
| 6 | €127 | −€448 |
| 7 | €127 | −€321 |
| 8 | €127 | −€195 |
| 9 | €127 | −€68 |
| 10 | €127 | €59 |
Marstek Venus E 3.0: Cash-flow scenario over 10 years
This repeats the reference-year saving. It is a scenario, not a forecast or a claim about how long the equipment will last.
10 years, 0.0% real discount rate. Prices and policy stay at the 2027 reference, including proposed tax rates where not final. Payments are counted at the end of each year after commissioning.
| Net present value after investment | −€58 |
|---|---|
| Cash balance after investment | −€58 |
| Discounted payback | Not within this scenario |
No equipment ageing, replacement, residual value or extra maintenance and supplier fees are assumed. Costs already included in the annual saving remain included. Imbalance-trading income is excluded.
| Year | Net cash flow | Balance after investment |
|---|---|---|
| 1 | €112 | −€1,062 |
| 2 | €112 | −€951 |
| 3 | €112 | −€839 |
| 4 | €112 | −€728 |
| 5 | €112 | −€616 |
| 6 | €112 | −€504 |
| 7 | €112 | −€393 |
| 8 | €112 | −€281 |
| 9 | €112 | −€170 |
| 10 | €112 | −€58 |
All specifications
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | Growatt AURA 5000 | Marstek Venus E 3.0 |
|---|---|---|
| Of 10 kWh in, you get back | 7.9–8.7 kWhestimate from the datasheet | 8.2–8.6 kWhone independent test |
| Reads your grid use via | P1 meter · clamp meter | P1 meter · clamp meter |
| Standby use | €17 a year | €12 a year |
| Feed-in left over | ≈ 940 kWh (without: 1,910) | ≈ 1,050 kWh (without: 1,910) |
| Savings from 2027 | €85–137 a year | €80–121 a year |
✓ Better for this home: only where the difference is larger than the uncertainty, with the reason under the row name. Unknown: not stated in the sources we use (datasheet, maker, shop).
Ordinary socket: 800 W at most. More power needs its own group.
Per example home
Show as table
| Home | Product | Payback |
|---|---|---|
| Terraced | Growatt AURA 5000 | ≈ 10 years (9–14 years) |
| Terraced | Marstek Venus E 3.0 | ≈ 11 years (10–15 years) |
| Semi-detached | Growatt AURA 5000 | ≈ 6 years (5–6 years) |
| Semi-detached | Marstek Venus E 3.0 | ≈ 6 years (6 years) |
| Heat pump | Growatt AURA 5000 | ≈ 7 years (6–9 years) |
| Heat pump | Marstek Venus E 3.0 | ≈ 8 years (7–10 years) |
Terraced: the figures
2,900 kWh a year, 3 kWp of solar panels, fixed contract
No winner over the whole range for this home: the likely payback ranges overlap. Where one product is ahead in nearly every case we calculated, the row says so.
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | Growatt AURA 5000 | Marstek Venus E 3.0 |
|---|---|---|
| Feed-in left over | ≈ 940 kWh (without: 1,910) | ≈ 1,050 kWh (without: 1,910) |
| Savings from 2027 | €85–137 a year | €80–121 a year |
| Payback | 9–14 years | 10–15 years |
Semi-detached: the figures
3,500 kWh a year, 5 kWp of solar panels, dynamic contract
No winner over the whole range for this home: the likely payback ranges overlap. Where one product is ahead in nearly every case we calculated, the row says so.
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | Growatt AURA 5000 | Marstek Venus E 3.0 |
|---|---|---|
| Feed-in left over | ≈ 2,350 kWh (without: 3,580) | ≈ 2,460 kWh (without: 3,580) |
| Savings from 2027 | €199–234 a year | €181–204 a year |
| Payback | 5–6 years | 6 years |
Heat pump: the figures
3,000 kWh household use plus a heat pump that replaced 1,200 m³ of gas, 6 kWp of solar panels, fixed contract
No winner over the whole range for this home: the likely payback ranges overlap. Where one product is ahead in nearly every case we calculated, the row says so.
Conditional model comparison. The household baseline or package cost scope is not confirmed, so this table does not establish which installation fits your home.
| Compared | Growatt AURA 5000 | Marstek Venus E 3.0 |
|---|---|---|
| Feed-in left over | ≈ 2,990 kWh (without: 4,240) | ≈ 3,140 kWh (without: 4,240) |
| Savings from 2027 | €134–189 a year | €123–169 a year |
| Payback | 6–9 years | 7–10 years |
Questions people ask
Which pays back sooner, the Growatt AURA 5000 or the Marstek Venus E 3.0?
For most homes, the Growatt AURA 5000 and the Marstek Venus E 3.0 pay back about equally fast, according to our calculation, but your own use and panels can change that. In the terraced house: Growatt AURA 5000 9–14 years, Marstek Venus E 3.0 10–15 years. In the terraced house: Growatt AURA 5000 9–14 years, Marstek Venus E 3.0 10–15 years. In the semi-detached house: Growatt AURA 5000 5–6 years, Marstek Venus E 3.0 6 years. In the home with a heat pump: Growatt AURA 5000 6–9 years, Marstek Venus E 3.0 7–10 years.
Which costs less per kWh of storage, the Growatt AURA 5000 or the Marstek Venus E 3.0?
The Growatt AURA 5000 costs €267 per usable kWh (€1,208, price of 1 October 2026); the Marstek Venus E 3.0 costs €255 per usable kWh (€1,174, price of 1 October 2026).
Do the Growatt AURA 5000 and the Marstek Venus E 3.0 have backup power?
Growatt AURA 5000: emergency socket, 2,500 W; Marstek Venus E 3.0: emergency socket, 2,500 W.
Do the Growatt AURA 5000 and the Marstek Venus E 3.0 work with a dynamic contract and Home Assistant?
Dynamic contract: Growatt AURA 5000: yes, in its own app (uncertain); Marstek Venus E 3.0: yes, in its own app. Home Assistant: Growatt AURA 5000: none; Marstek Venus E 3.0: community integration.
How did you calculate this?
With our own engine, for 3 invented example homes, hour by hour under the rules from 2027 (no net metering), with the prices in our catalogue. Each result is a range over 22 variants of the same home: how you use power, the direction of the panels, the weather and the energy price. We only mark a product better when it is ahead in at least 9 of 10 of those cases.